G5310 Gas Concentration Analyzer (Ангилья - Тендер #37854852) | ||
| ||
| Для перевода текста тендера на нужный язык воспользуйтесь приложением: | ||
Страна: Ангилья (другие тендеры и закупки Ангилья) Организатор тендера: Sell2Wales – Government´s Initiative Номер конкурса: 37854852 Дата публикации: 27-01-2023 Источник тендера: Sell2Wales – Government´s Initiative |
||
Directive 2014/24/EU
Section I: Contracting entity I.1) Name and addressesNational Physical Laboratory
Hampton Road
Teddington
TW11 0LW
UK
Contact person: Gary Phillips
Telephone: +44 2089773222
E-mail: gary.phillips@npl.co.uk
NUTS: UK
Internet address(es)
Main address: www.npl.co.uk
I.4) Type of the contracting authorityBody governed by public law
I.5) Main activityOther: Research
Section II: Object II.1) Scope of the procurement II.1.1) TitleG5310 Gas Concentration Analyzer
Reference number: 127701
II.1.2) Main CPV code38000000
II.1.3) Type of contractSupplies
II.1.4) Short descriptionThe Picarro G5310 gas concentration analyzer provides simultaneous, precise measurement of nitrous oxide (N2O), carbon monoxide (CO) at parts-per-trillion (ppt), and water (H2O) vapor at parts-per-million (ppm) sensitivity with negligible drift for atmospheric science, air quality, and emissions quantification.
II.1.6) Information about lotsThis contract is divided into lots: No
II.1.7) Total value of the procurementValue excluding VAT: 130 000.00 GBP
II.2) Description II.2.3) Place of performanceNUTS code:
UK
II.2.4) Description of the procurementThe Picarro G5310 gas concentration analyzer provides simultaneous, precise measurement of nitrous oxide (N2O), carbon monoxide (CO) at parts-per-trillion (ppt), and water (H2O) vapor at parts-per-million (ppm) sensitivity with negligible drift for atmospheric science, air quality, and emissions quantification. It meets the World Meteorological Organization (WMO) and Integrated Carbon Observation System (ICOS) performance requirements for N2O and CO atmospheric monitoring.
Simultaneous and continuous measurement of N2O and CO
Mid-IR CRDS for high precision and low drift analysis
Compliant with WMO and ICOS international ambient atmospheric monitoring requirements
Water correction automatically reports dry gas mole fractions
Precision at 5 seconds and 5 minutes is <200 and <40 ppt for N2O and for CO. Drift at standard temperature and pressure (STP) over 24 hours is <100 ppt for N2O and for CO. Water correction software automatically reports dry gas mole fractions to help reduce research complexity and consumable costs.
II.2.11) Information about optionsOptions: No
II.2.13) Information about European Union fundsThe procurement is related to a project and/or programme financed by European Union funds: No
Section IV: Procedure IV.1) Description IV.1.1) Type of procedureAward of a contract without prior publication of a call for competition
Justification for selected award procedure:
The procurement falls outside the scope of application of the Directive
Explanation:
Competition is absent for technical reasons: Amiston is the only vendor that can provide this Picarro equipment to the required specification.
IV.1.8) Information about Government Procurement Agreement (GPA)The procurement is covered by the Government Procurement Agreement: Yes
Section V: Award of contract/concessionContract No: 127701
Title: G2401 Gas Concentration Analyzer
V.2 Award of contract/concession V.2.1) Date of conclusion of the contract/concession24/01/2023
V.2.2) Information about tendersThe contract has been awarded to a group of economic operators: No
V.2.3) Name and address of the contractorAmiston Limited
11 Weston Park
Bath
BA1 4AS
UK
NUTS: UK
The contractor is an SME: No
V.2.4) Information on value of the concession and main financing terms (excluding VAT)Initial estimated total value of the contract/lot/concession: 130 000.00 GBP
Total value of the concession/lot: 130 000.00 GBP
V.2.5) Information about subcontractingThe contract/concession is likely to be subcontracted
Section VI: Complementary information VI.4) Procedures for review VI.4.1) Review bodyNPL Management Limited
Hampton Road
Teddington
TW11 0LW
UK
VI.5) Date of dispatch of this notice26/01/2023
Information added to the notice since publication.
Additional information added to the notice since it"s publication.| No further information has been uploaded. |
| Main Contact: | gary.phillips@npl.co.uk |
| Admin Contact: | N/a |
| Technical Contact: | N/a |
| Other Contact: | N/a |
| ID | Title | Parent Category |
|---|---|---|
| 38000000 | Laboratory, optical and precision equipments (excl. glasses) | Technology and Equipment |
| ID | Description |
|---|---|
| 100 | UK - All |
The buyer has restricted the alert for this notice to suppliers based in the following regions.
Alert Region Restrictions| There are no alert restrictions for this notice. |