GOC6689050 - CS - GOC6689050 - CS LTES Freezer (Канада - Тендер #69769862) | ||
| ||
| Для перевода текста тендера на нужный язык воспользуйтесь приложением: | ||
Страна: Канада (другие тендеры и закупки Канада) Организатор тендера: www.merx.com Номер конкурса: 69769862 Дата публикации: 08-01-2026 Источник тендера: www.merx.com |
||
0000310979
Issuing OrganizationBGIS - PWGSC RP1
Solicitation TypeRFP - Request for Proposal (Formal)
Solicitation NumberGOC6689050 - CS
TitleGOC6689050 - CS LTES Freezer
Source IDPU.DP.Que..8088.29965.C826102
Canada, Saskatchewan, All of Saskatchewan
Description
Scope of Work/Overview:
Objective:
1) Make this freezer system align with the Federal Government Greening policies. Low GWP (global warming potential) refrigerant to be used.
2) Operate at new lower temperature of -20 deg. C.
Additional Description:
Design freezer system to run at -20 Celsius. (existing system is currently running at -16 Celsius) In order to align with the Federal Government Greening policies, newer low temperature and low
global warming potential (GWP) refrigerant is to be used. Design control system to allow a lead lag operation of both separate freezer systems. 24hrs on, 24hrs off for both systems. Power must
be run to the freezer system and evaporator. Drainage from the evaporator must be tied into the existing drainage. Heat trace tape to be installed as part of the overall installation to prevent
drainage water from freezing. EEV (Electronic Expansion Valve) will be installed as the metering device & pump down control (to mitigate solenoid issues, the current system is showing that
this is an issue). RCMP to be presented with the option of a single Hermetic Compressor, and scroll compressor options.
-Add redundant secondary freezer compressor/evaporator. Consultant to verify size calculation and cooling capacity.
-One suggested model of compressor is Keeprite Tonnage 15.902 (75HP), 575V, Model # KESA075L6-HT5B-24576, Serial # 172104801
-Existing freezer: Refrigerant and/or condensor or other equipment/components to be reviewed, refrigerant replaced with low GHG potential, and any other required components to maintain
compatibility with new coolant and cooler operating temperature of -20 deg. C, to be replaced.
-Consultant to do comprehensive site investigation to determine full as-built condition.
-Current freezer is in main floor, Rm. 114. (Exact configuration to be determined based on investigation by consultant.)
-During this project LTES exhibits to be temporary moved to the DNA Repository freezer at HQ.
Jan 07, 2026 03:49 PM CST
Bid IntentNot Available
Question Acceptance DeadlineJan 21, 2026 02:00 PM CST
Questions are submitted onlineYes
Closing DateJan 23, 2026 02:00 PM CST
Onsite VisitJan 15, 2026 09:30 AM CST
Denise Sandulak
204-333-6294
Denise.Sandulak@bgis.com
Acknowledgement
By submitting our response to this solicitation, we confirm that we have read and agree to comply with the terms and conditions of this ITT, and we agree to provide, upon request, all
documentation without modification as defined in this ITT. BGIS reserves the right to reject our submission should BGIS fail to receive the required documentation.
Onsite Visit
AttendanceRecommended
Event dateJan 15, 2026 09:30 AM CST
LocationRCMP F DIVISION SUPPORT SERVICES BLD. #FBU323
Event Note
Recommended On-Site Visit on Thursday, January 15, 2026 at 9:30 am
Meet BGIS Tech or Project Manager at sign in Desk
Security Requirements: DOS and Reliability
All individual attending the site visit must bring their own Personal Protection Equipment (PPE)
All Covid-19 Guidelines must be followed.
Electronic Bid Submission
No pricing in this envelope
Bid Documents List| Item Name | Description | Mandatory | Limited to 1 file |
|---|---|---|---|
| Bid Documents | Documents defining the proposal | Yes | No |
| No entries | |||
Lump sum
Bid Documents List| Item Name | Description | Mandatory | Limited to 1 file |
|---|---|---|---|
| Bid Documents | Documents defining the proposal | Yes | No |
| No entries | |||
Property Management Supplier Compliance (BGIS - RP4)