Description
CONTACT INFORMATION|4|N742.13|ER6BB|N/A|seana.m.steiner.civ@us.navy.mil| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY
REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999)|1|ISO9001| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION AND ACCEPTANCE - SHORT VERSION|8|x||x|||||| TIME OF DELIVERY (JUNE
1997)|20|CLIN 0001|25|642|||||||||||||||||| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications; COMBO - Receiving Report & Invoice -
Material |Material - Inspect & Accept at Source|TBD|N00104|TBD|TBD|W25G1U, W62G2T|TBD|N/A|N/A|N/A|N/A|N/A|N/A|SEE FORM DD1423| 1-866-618-5988 - WAWF Helpdesk.| NOTE FOR
CONTRACTOR/ADMINISTRATIVE CONTRACTING OFFICER|3|||| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|WSS| VALUE ENGINEERING (JUN 2020)|3|||| EQUAL
OPPORTUNITY (SEP 2016)|2||| INTEGRITY OF UNIT PRICES (NOV 2021)|1|| EQUAL OPPORTUNITY FOR VETERANS (JUN 2020)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year
from date of delivery.|One year from date of delivery.||||| WARRANTY OF DATA--BASIC (MAR 2014)|2||| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (JUN 2020)|2||| FIRST ARTICLE
APPROVAL--CONTRACTOR TESTING (SEP 1989)|10|1|0001AA|7|642|ATTN: TBD Naval Supply Systems Command 5450 Carlisle Pike, Suite 412-D18 Mechanicsburg, PA 17050|TBD|0001AA|90|x|| BUY AMERICAN
--FREE TRADE AGREEMENTS--BALANCE OF PAYMENTS PROGRAM - BASIC (FEB2024))|11|||||||||||| NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (OCT 2020)(DEVIATION 2020-O0008)|1|| ALTERNATE A, ANNUAL
REPRESENTATIONS AND CERTIFICATIONS (NOV 2023)|13||x|||||||||||| SMALL BUSINESS PROGRAM REPRESENTATIONS (FEB 2024)|4|335931|600||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS
PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (FEB
2024)|13|335931|600|||||||||||| INSTRUCTIONS TO OFFERORS -- COMPETITIVE ACQUISITION (NOV 2021)|2||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY
PROGAM USE (APRIL 2008))|2||x| EVALUATION OF FIRST ARTICLE TESTING|3|||| 1. This requirement is pursuant to Emergency Acquisition Flexibilities (EAF). 2. The resultant award of this
solicitation shall be issued bilaterally, requiring the contractors written acceptance prior to execution. 3. When submitting a quote, specify any exceptions (I.e. MIL-STD Packaging,
MIL-STD Labeling, Inspection & Acceptance locations, Packaging House, surplus material, etc.). If no exceptions are indicated or received, award shall be based upon solicitation
requirements. Changes or requests for changes after award shall be subject to consideration costs deducted from the unit price. 4. All contractual document (i.e. contracts, purchase
orders, task orders, delivery orders and modifications) related to the instant procurement are considered to be "issued" by the Government when copies are either deposited in the mail,
transmitted by facsimile, or sent by other electronic commerce method such asemail. The Governments acceptance of the contractors proposal constitutes bilateral agreement to "issue"
contractual documents as detailed herein. 5. Any contract awarded as a result of this solicitation will be DO certified for national defense under the Defense Priorities and Allocations
System (DPAS).Provision 52.211-14, Notice of Priority Rating for National Defense, Emergency Preparedness, and Energy Program Use, shall be inserted in solicitations when the contract to
be awarded will be a rated order. 1. SCOPE 1.1 ;This procurement specification contains the requirements for manufacture and the contract quality requirements for ;AN/BRR-6 Outboard Cable
Assembly (6W45/6W46); for use on Navy submarines.; 2. APPLICABLE DOCUMENTS 2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including
modifications or exclusions. 2.1.1 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made. 2.1.2 "Document
References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.1.3 The "Document Changes" section
provides supersessions/changes to referenced documents. 2.2 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or
drawings cited herein, the text of this contract/purchase order shall take precedence. Nothing in this contract/purchase order, however, shall supersede applicable laws and regulations
unless a specific exemption has been obtained. DRAWING DATA=8590851 |53711| B| |D|0001 | B|49998|0095679 DRAWING DATA=8590854 |53711| -| |D|0001 | -|49998|0080043 DRAWING DATA=8603517
|53711| -| |D|0001 | -|49998|0255963 DOCUMENT REF DATA=MIL-STD-130 | | |N |121116|A| |01| DOCUMENT REF DATA=MIL-DTL-915 | | |G |100908|A| | | DOCUMENT REF DATA=MIL-DTL-915 |0048| |D
|020822|A| | | DOCUMENT REF DATA=MIL-STD-973 | | | |950113|A| |03| DOCUMENT REF DATA=ISO9001 | | | |150915|A| | | DOCUMENT REF DATA= ISO 10012 | | | |030415|A| | | DOCUMENT REF
DATA=MIL-M-24041 | | |C |881220|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A|1 | | DOCUMENT REF DATA=NCSL Z540.3 | | | |060803|A| | | DOCUMENT REF DATA=A-A-56032 | | |D
|140930|A| | | DOCUMENT REF DATA=SAE-AMS2817G - 05/22 | | | | |A| | | DOCUMENT REF DATA=SAE-AS28775A - 11/2013 | | | | |A| | | DOCUMENT REF DATA=SAE-AS23053/1A - 03/2018 | | | | |A| | |
DOCUMENT REF DATA=S9320-AM-PRO-020/MLDG-08/1999 | | |02 |990801|A| | | DOCUMENT CHANGE DATA=AMS-2817 |SAE-AMS2817G 3. REQUIREMENTS 3.1 ;Design and Manufacturing - The ;AN/BRR-6 Outboard
Cable Assembly (6W45/6W46); furnished under this contract/purchase order shall meet the material, electrical, mechanical, physical and test requirements as specified on Drawings 8590851
(consisting of Item Numbers 1 thru 7,9), 8590854 and 8603517, NAVSEA Manual S9320-AM-PRO-020/MLDG and including associated specifications mentioned in this procurement. ; 3.1.1 ;The
AN/BRR-6 6W45/6W46 Mold Assembly shall be manufactured per the guidance of Drawing 8603517 (consisting of Item Numbers 1 thru 12) as required by Drawing 8590851.; 3.1.2 ;The Polyurethane
Molding Compound Type II, Color Amber shall be in accordance with MIL-M-24041 requirements as specified on Drawing 8590851.; 3.1.3 ;All outboard molded cable assemblies shall be
manufactured and tested in accordance with NAVSEA Manual S9320-AM-PRO-020/MLDG requirements as specified on Drawings 8590851, Note 4 and 8590854, Note 4.; 3.2 ;Vendor Qualification. As
required by Drawing 8590854:; 3.2.1 ;Only vendors which are qualified, per the audit requirements of NAVSEA Manual S9320-AM-PRO-020/MLDG Appendix II-A, and listed on the approved vendors
lists in appendix II-A of NAVSEA Manual S9320-AM-PRO-020/MLDG, shall be authorized to fabricate submarine outboard cable assemblies.; 3.3 ;Marking Requirements - The supplier shall
permanently mark and identify each first article and production lot unit ;Cable Assembly; in accordance with Notes 6 and 7 of Drawing 8590851 per MIL-STD-130. ;Per Note 5 of Drawing
8590851, the supplier shall contact Jason Krol, jason.a.krol2.civ@us.navy.mil of NSWC Philadelphia Division for component serial number information.;; 3.3.1 ;The supplier shall mark ;tag
or bag; all piece parts with contract, drawing/ item, heat, lot or batch and serial number in accordance with MIL-STD-130 until installed in the designated assembly.; 3.4 ;First Article
Testing/Inspection - (Supplier Testing/Inspection). The first article testing/inspection procedure and approval are required for the ;Cable Assembly;. Government approval is required
prior to commencement of first article unit.; 3.5 ;Notification - The supplier shall notify Naval Surface Warfare Center, Philadelphia Division, (NSWCPD), 5001 S. Broad Street,
Philadelphia, PA 19112-1403 by email matthew.j.ogilvie.civ@us.navy.mil, Code 242MO after award of contract.; 3.5.1 ;The NSWCPD is the acceptance activity for the Contract Data
Requirements List (DD1423) Data Items. NSWCPD WAWF/IRAPT ;Acceptor; DODACC is ;N64498;.; 3.6 Configuration Control - MIL-STD-973 entitled "Configuration Management", Paragraph 5.4.8,
Configuration Control (Short Form Procedure), is hereby incorporated. The Contractor shall submit all Engineering Change Proposals in accordance with MIL-STD-973, Paragraph 5.4.8.2 and
Appendix D. Requests for Deviations shall be processed in accordance with MIL-STD-973, Paragraph 5.4.8.3 and Appendix E. Requests for Waivers shall be processed in accordance with
MIL-STD-973, Paragraph 5.4.8.4 and Appendix E. (Original and two copies shall be submitted to Contracting Officer, NAVICP-MECH, P. O. Box 2020, Mechanicsburg Pa. 17055-0788.) 3.6.1
Configuration Control - When the Contractor has received authorization on a prior contract for the same NSN for the use of a drawing of a later revision status, that authorization is
hereby extended to all succeeding contracts/purchase orders until another drawing revision is approved. The Contractor will notify the PCO of this occurrence in each instance, in the
response to the solicitation. Such notification shall be in writing setting forth the contract under which the prior authorization was granted, the date of the granting of the
authorization, and the name of the granting authority. Contractors shall also refer technical inquiries (other than those covered by MIL-STD-973) on company letterhead signed by a
responsible company official, with copies distributed as stated below. The original and two copies of all Contractor generated correspondence regarding configuration shall be submitted to
Contracting Officer, NAVICP-MECH, P.O. Box 2020, Mechanicsburg, PA 17055-0788. Contractors are cautioned that implementing engineering changes, waivers, deviations or technical inquiries
into the contract/purchase order without approval of the Contracting Officer will be at the sole risk of the Contractor. 3.7 Mercury Free - The material supplied under this
contract/purchase order is intended for use on submarines/surface ships and therefore shall contain no metallic mercury and shall be free from mercury contamination. Mercury contamination
of the material will be cause for rejection. If the inclusion of metallic mercury is required as a functional part of the material furnished under this contract, the Contractor shall
obtain written approval from the Procurement Contracting Officer before proceeding with manufacture. The contractors request shall explain in detail the requirements for mercury, identify
specifically the parts to contain mercury, and explain the method of protection against mercury escape. Such a request will be forwarded directly to the Procurement Contracting Officer
with a copy to the applicable Government Inspector. Upon approval by the Contracting Officer, the vendor will provide a "Warning Plate" stating that metallic mercury is a functional part
of the item and will include name and location of that part. The use of mercury, mercury compounds, or mercury-bearing instruments and/or equipment in a manner which might cause
contamination in the manufacture, assembly, or test of material on this contract is prohibited. The most probable causes of contamination are direct-connected manometers, mercury vacuum
pumps, mercury seals, or the handling of mercury in the immediate vicinity. Mercury switches, mercury in glass thermometers, standard cells and other items containing mercury may be used
if they are located so as not to constitute a contamination hazard. If external contamination by metallic mercury occurs or is suspected, the following test may be used to determine
whether contamination by metallic mercury exists or whether corrective cleaning measures have been effective. Enclose the equipment in a polyethylene bag or close-fitting airtight
container for eight hours at room temperature (70 degrees F minimum).Sample the trapped air and if mercury vapor concentration is 0.01 mg/cu meter or more, the material is mercury
contaminated insofar as the requirements of this contract are concerned. These requirements shall be included in any subcontract or purchase order hereunder and the Contractor shall
insure SubContractor compliance with these requirements. Technical questions pertaining to these requirements shall be referred to the Procurement Contracting Officer via the cognizant
Administrative Contracting Officer. For background, the following information is provided: Mercury is corrosive to gold, silver, nickel, stainless steels, aluminum and copper alloys.
Stainless steels, nickel, and copper alloys are widely used in reactor plants and other submarine/surface ship systems. Accidental trapping of mercury in a component could cause serious
damage to vital parts. Mercury is also toxic if inhaled, ingested, or absorbed through the skin. It is evident that grave consequences could result from small amounts of mercury vapor
present in an unreplenished submarine/surface ship atmosphere. 4. QUALITY ASSURANCE 4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the
Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order, the Contractor may use his
own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to
perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2
Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractors
overall inspection system or quality program. The absence of any inspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies
submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance does not authorize submission of known defective
material, either indicated or actual, not does it commit the Government to acceptance of defective material. 4.3 Records - Records of all inspection work by the Contractor shall be kept
complete and available to the Government during the performance of contract/purchase order and for a period of 365 calendar days after final delivery of supplies. 4.4 ;Inspection System -
The Suppliers Quality Inspection System shall be in accordance with MIL-I-45208 or ISO 9001 and NCSL Z540.3 or ISO 10012. The supplier shall develop and submit their written Quality
Inspection and Test Plan as indicated on the Contract Data Requirements List (DD Form 1423). Government approval of the suppliers written Quality Inspection and Test Plan is required by
the contract. CDRL: QUALITY INSPECTION & TEST PLAN per MIL-I-45208, NCSL Z540.3 and DI-QCIC-81110 ; 4.5 ;Finished Edges - Finished shall be in accordance with the applicable drawing
requirements. ; 4.6 ;Material Control - The supplier shall have an effective material control system that provides for the control of materials by heat, lot or batch as ordered for first
article and production lot units. ; 4.7 ;First Article Testing/Inspection - (Supplier Testing/Inspection). The supplier shall perform first article testing/inspection on ;Cable Assembly;
in accordance with the applicable drawings and specifications, NAVSEA manual S9320-AM-PRO-020/MLDG, and their approved first article procedure.; 4.7.1 ;The first article inspection shall
be made by the cognizant DCMA-QAR at the suppliers and/or subcontractor facility. The supplier shall notify NSWCPD, Code 242MO two weeks in advance prior to the scheduled first article
testing/inspection, so an NSWCPD representative has the option of being present during the first article testing/inspection.; 4.8 ;First Article Approval for Testing/Inspection Procedure
and Acceptance - (Supplier Testing/Inspection). The supplier shall prepare and submit their First Article Testing/ Inspection Procedure for ;Cable Assembly; in accordance with the
requirements of DI-NDTI-80603, the applicable drawings and specifications, NAVSEA S9320-AM-PRO-020/MLDG, and as indicated on the Contract Data Requirements List (DD Form 1423). Government
approval of the procedure is required prior to commencement of first article unit. CDRL: FIRST ARTICLE TESTING/INSPECTION PROC per DI-NDTI-80603A; 4.9 ;First Article Testing/Inspection
;Cable Assembly; - The supplier shall perform 100% examination, inspection and testing on the completed first article unit (bulk cable/component parts/assembly) in accordance with the
applicable drawings, NAVSEA S9320-AM-PRO-020/MLDG, and their approved first article procedure. The supplier shall record the actual measurements and readings results of each examination,
inspection and test in NAVSEA S9320-AM-PRO-020/MLDG, and each dimension identified on the applicable drawings.; 4.9.1 ;The supplier shall visually inspect and perform electrical
continuity and dc insulation resistance testing 100% on the ;Bulk Cable; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.9.2 ;The supplier shall visually and physically
inspect 100% the connectors (Item Nos. 3 and 4 of drawing 8590851) in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.9.3 ;The supplier shall visually and physically inspect
100% the completed ;Cable Assembly; of each dimension and keyway location/position identified on Drawing 8590851 including the identification and markings required by Notes 6 and 7 of the
drawing.; 4.9.4 ;The supplier shall visually inspect 100% the molded plug connectors on the completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.9.5
;The supplier shall perform 100% electrical continuity test on the completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.9.6 ;The supplier shall
perform 100% insulation resistance test on the completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.9.7 ;The supplier shall perform 100%
nondestructive bonding test on molded plug connectors on the completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.9.8 ;The supplier shall perform
100% hydrostatic pressure test on the completed ;Cable Assembly; including insulation resistance testing in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.10 ;First Article
Testing/Inspection Report and Acceptance - (Supplier Testing/Inspection). The supplier shall submit for completed first article unit ;Cable Assembly; testing/inspection reports in
compliance with the requirements of DI-NDTI-80603, the applicable drawings and specifications, NAVSEA manual S9320-AM-PRO-020/MLDG. The report shall also include a copy of ;Bulk Cable
Inspection/ Test Report (Type 2SWF-3 per MIL-DTL-915/48); Certificate of Conformance for: Materials, (Polyurethane Molding Compound, Backfill Material and Primer); Certificate of
Compliance for Connectors and Polychloroprene Material Per MIL-DTL915; Bulk Cable Inspection/Test Report per NAVSEA S9320-AM-PRO-020/MLDG; identified in the Objective Quality Evidence
Records section of this document, and as indicated on the Contract Data Requirements List (DD Form 14230. Government approval of the first article testing/inspection report is required
prior to commencement of production units. CDRL: FIRST ARTICLE TESTING/INSPECTION REPORTS per DI-NDTI-80809B; 4.11 ;Production Lot. ; 4.12 ;Bulk Cable - The supplier shall perform 100%
examination, inspection and testing on the production lot (Bulk Cable, Type 2SWF-3) in accordance with the applicable requirements listed in specification MIL-DTL-915/48 (Quality
Conformance Inspection) Basic Electrical,Groups A, B, and C. The supplier shall record the actual measurements and results of each examination, inspection and test specified in the
applicable specification.; 4.13 ;Cable Assembly. The supplier shall perform 100% examination, inspection and testing on each completed production lot unit (bulk cable/component
parts/assembly) in accordance with the applicable drawings and NAVSEA S9320-AM-PRO-020/MLDG. The supplier shall record the actual measurements and results of each examination, inspection
and test in NAVSEA S9320-AM-PRO-020/MLDG and each dimension identified on the applicable drawings.; 4.13.1 ;The supplier shall visually inspect and perform electrical continuity and dc
insulation resistance testing 100% on the ;Bulk Cable; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.13.2 ;The supplier shall visually and physically inspect 100% each
connector (Item Nos. 3 and 4 of drawing 8590851) in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.13.3 ;The supplier shall visually and physically inspect 100% each
completed ;Cable Assembly; of each dimension and keyway location/position identified on Drawing 8590851 including the identification and markings required by Notes 6 and 7 of the
drawing.; 4.13.4 ;The supplier shall visually inspect 100% the molded plug connectors on each completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.;
4.13.5 ;The supplier shall perform 100% electrical continuity test on each completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.13.6 ;The supplier
shall perform 100% insulation resistance test on each completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.13.7 ;The supplier shall perform 100%
nondestructive bonding test on molded plug connectors on each completed ;Cable Assembly; in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.13.8 ;The supplier shall perform
100% hydrostatic pressure test on each completed ;Cable Assembly; including insulation resistance testing in accordance with NAVSEA S9320-AM-PRO-020/MLDG requirements.; 4.13.9 ;The
supplier shall conduct pre-shipment inspection and verification of connector O-Rings (Item Nos. 6 and 9) are individually packed and shipped with unit in accordance with Note 3 of Drawing
8590851 and NAVSEA S9320-AM-PRO-020/MLDG. ; 4.14 ;Production Lot Testing/Inspection Report and Acceptance - (Supplier Testing/ Inspection). The supplier shall submit for the completed
production units ;Cable Assembly; testing/inspection reports in compliance with applicable Data Item Descriptions (DIDs), drawings and specifications, NAVSEA manual S9320-AM-PRO-020/MLDG.
The Production Lot Testing/Inspection report shall consist of ;Bulk Cable Inspection/Test Report (Type 2SWF-3 per MIL-DTL-915/48);Certificate of Conformance for Materials (Polyurethane
Molding Compound, Backfill Material and Primer);Certificate of Compliance for Connectors and Polychloroprene Material per MIL-DTL-915; Bulk Cable Inspection/Test Report per NAVSEA
S9320-AM-PRO-020/MLDG; identified in the Objective Quality Evidence Records Section of this document, and as indicated on the Production Lot Test/Inspection (PLT) Contract Data
Requirements List (DD Form 1423). Government approval of the production lot testing/inspection report is required prior to shipment of production lot units. CDRL: PRODUCTION LOT
TESTING/INSPECTION REPORT per DI-NDTI-80809B; 4.15 ;AN/BRR-6 6W45/6W46 Mold Assembly Drawing 8603517 Material/Inspection Requirements:; 4.15.1 ;The supplier shall provide material
certification for 6W45/6W46 Mold Assembly, Item Numbers 2, 3, 5, 6 and 12 of the applicable drawing 8603517 (certifying items to drawing and applicable material requirements). Records
shall be traceable by drawing/item, heat, lot or batch, serial and contract number. CDRL: CERTIFICATE OF COMPLIANCE per DI-MISC-82386 ; 4.15.2 ;The supplier shall perform visual and
physical inspection 100% on each mold machined part (Item Numbers 2, 3, 5, 6 and 12) of each dimension identified on drawing 8603517 including threads. Threads shall be inspected 100% and
results recorded. The supplier shall record the actual measurements and results of each dimension identified on the on the applicable drawing including threads, the applicable
identification and markings required by Drawing 8603517. The inspection reports shall show all the characteristics, the actual measurements and results of each dimension inspected,
including threads, identification and markings, contract number, name of supplier, drawing/item number, drawing revision letter, heat, lot or batch, serial number, item nomenclature,
inspectors acceptance signature and date. CDRL: VISUAL/DIMENSIONAL INSPECTION REPORT per DI-NDTI-80809B; 4.15.3 ;AN/BRR-6 6W45/6W46 Mold Assembly Material/Inspection Report and Acceptance
- (Supplier Test/Inspection). The supplier shall submit material certification/ inspection report in compliance with the applicable Data Item Descriptions (DIDs) and Drawing 8603517. The
Material/Inspection report shall consist of ;Certificate of Compliance for Material (Item Numbers 2,3,5,6 and 12 of the drawing) and Visual/Dimensional Inspection Report (Item Numbers
2,3,5,6 and 12 of the drawing; identified in the above respective paragraphs, and as indicated on the Contract Data Requirements List (DD Form 1423). Government approval of the suppliers
certification/inspection report is required prior to commencement of first article unit. CDRL: MOLD ASSEMBLY (DRAWING 8603517) MATERIAL CERTIFICATION/ISPECTION REPORT per DI-NDTI-80809B;
4.16 ;Production Lot Inspection/Acceptance - (Supplier Testing/Inspection). The supplier shall submit for the production lot units, the inspection and test reports identified in the
Objective Quality Evidence Records Section of this document and as indicated on the Production Lot Testing/Inspection (PLT) Contract Data Requirements List (DD Form 1423). Government
approval is required prior to shipment of production units.; 4.17 ;Final Inspection and Acceptance - Final inspection and acceptance of production lots shall be made by the cognizant
DCMA-QAR in conjuction with the Specific Government Inspection Instructions (SGIIs) furnished by NSWCPD. In addition to the normal DCMA surveillance, the production unit(s) shall be under
the surveillance of NSWCPD Quality Assurance Specialist as required.; 4.18 ;Objective Quality Evidence Records - The supplier shall maintain Objective Quality Evidence Data (OQEDs) of raw
material and finished parts of ;Cable Assembly;. Records shall be traceable by drawing/item, heat, lot or batch, contract and assembly serial number. All OQEDS shall be clearly legible
including name and title. The supplier may provide exact (quality) photocopies of objective quality evidence records being delivered under this purchase order instead of originals.;
4.18.1 ;The supplier shall furnish a copy of the following OQEDs listed below and as indicated on the Contract Data Requirements List (DD Form 1423) for acceptance. The reports shall be
correlated to the drawing/item, heat, lot or batch, contract and assembly serial number. Supplier format is acceptable for the below listed CDRLs. a. The supplier shall submit Production
Lot (Bulk Cable, Type 2SWF-3) Examination, Inspection and Test Reports in accordance with the applicable requirements listed in specification MIL-DTL-915/48 (Quality Conformance
Inspection) Basic Electrical, Groups A, B, and C. The reports shall show all the characteristics, the actual measurement and results of each examination, inspection and testing units
tested including contract number, name of supplier, specification number/date, bulk cable master reel, manufacturer part, test start and stop times, gauge serial number, gauge calibrated
date/due date of finished bulk cable, item nomenclature and inspectors acceptance signature and date. CDRL: PRODUCTON LOT (BULK CABLE) REPORT per DI-NDTI-80809B b. Certificate of
Conformance for: (1) Materials (certifying Item Nos. 6 and 9 materials to drawing 8590851 and the applicable specification requirements). (2) Polyurethane Molding Compound Material Type
II, Color Amber (certifying material, type and color has not exceeded the shelf life recommended by the manufacturer as required by MIL-M-24041). (3) Back Fill Material and Primer per
NAVSEA S9320-AM-PRO-020/MLDG (certifying material and type has not exceeded the shelf life recommended by the manufacturer). CDRL: CERTIFICATE OF CONFORMANCE per DI-MISC-82386 c.
Certificate of Compliance for: (1) Connector (certifying Item Nos. 3 and 4 to drawing 8590851 and the applicable manufacture part number requirements). (2) Polychloroprene Material
(certifying material to drawing 8590854 and MIL-DTL-915 requirements). CDRL: CERTIFICATE OF COMPLIANCE per DI-MISC-82386 d. The supplier shall submit Production Lot (Bulk Cable for
Drawing 8590851, Item No. 5/Type 2SWF-3) Examination, Inspection and Test Reports (consisting of Visual Inspection, Electrical Continuity Test, and Insulation Resistance Test in
accordance with NAVSEA Manual S9320-AM-PRO-020/MLDG, Appendix II D Data Sheets DS1, DS2 and DS3. The reports shall also include the contract number, name of supplier, drawing/item number,
drawing revision letter, specification number/date, bulk cable master reel, item nomenclature and inspectors acceptance signature and date. CDRL: PRODUCTON LOT (BULK CABLE) REPORT per
DI-NDTI-80809B e. The supplier shall submit Production Lot (Outboard Cable Assembly, 6W45/6W46) Examination, Inspection and Testing Reports (consisting of Visual Inspection of molded
connectors, Electrical Continuity Test, Insulation Resistance Test, Nondestructive and Destructive Bonding Test on molded connectors, Hydrostatic Pressure Test and Pre-Shipment
Inspection/Verification (Item Nos. 6 and 9) of drawing 8590851) in accordance with NAVSEA Manual S9320-AM-PRO-020/ MLDG, Appendix II D Data Sheets DS4 thru DS9. The reports shall also
include cable assembly dimensional inspection (drawing 8590851), contract number, name of supplier, drawing/item number, drawing revision letter, cable assembly serial, item nomenclature
and inspectors acceptance signature and date. CDRL: PRODUCTON LOT (CABLE ASSEMBLY) REPORT per DI-NDTI- 80809B f. Mercury Exclusion Certification (representing the contract units shipment)
CDRL: MERCURY EXCLUSION CERTIFICATION per DI-MISC-82386; 5. PACKAGING 5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in
accordance with the Contract/Purchase Order Schedule and as specified below. MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES 6.1 Ordering Information for
Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of
Specifications and Standards (DODISS) (i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. A. Availability of Cancelled Documents
- The DODSSP offers cancelled documents that are required by private industry in fulfillment of contractual obligations in paper format. Documents can be requested by phoning the
Subscription Services Desk. B. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. They
may be obtained from the publishers of the applicable societies. C. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be
obtained by submitting a request to: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410P, 101 Strauss Avenue Indian Head, MD 20640-5035 D. On post-award actions,
requests for "Official Use Only" and "NOFORN" (Not Releasable To Foreign Nationals) documents must identify the Government Contract Number, and must be submitted via the cognizant Defense
Contract Management Command (DCMC) for certification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document.
E. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from: Contracting Officer NAVICP-MECH Code
87321 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 F. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard,
NAVSEA 250-1500-1) are to be ordered from: Commanding Officer NAVICP-MECH Code 009 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 G. Technical Manuals Assigned NAVSEA
Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from: Naval Inventory Control Point Code 1 Support Branch 700 Robbins
Avenue Phildelphia, Pa. 19111-5094 H. Interim Changes and Classified Specifications shall be obtained by submitting a request on DD Form 1425 to NAVICP-MECH. DATE OF FIRST
SUBMISSION=ASREQ ;;APPROVAL OF THE QUALITY INSPECTION PLAN BY NSWC PHILADELPHIA DIVISION IS REQUIRED PRIOR TO FIRST ARTICLE.;; ;;NSWCPD IS THE ACCEPTANCE ACTIVITY FOR CDRL DATA ITEM A001.
NSWCPD WAWF/IRAPT ACCEPTOR DODACC IS "N64498".;; DATE OF FIRST SUBMISSION=ASREQ ;;APPROVAL OF THE PROCEDURE BY NSWC PHILADELPHIA DIVISION IS REQUIRED PRIOR TO COMMENCEMENT OF FIRST
ARTICLE UNIT.;; ;;NSWCPD IS THE ACCEPTANCE ACTIVITY FOR CDRL DATA ITEM A002. NSWCPD WAWF/IRAPT ACCEPTOR DODACC IS "N64498".;; DATE OF FIRST SUBMISSION=ASREQ ;;APPROVAL OF THE REPORT BY
NSWC PHILADELPHIA DIVISION IS REQUIRED PRIOR TO COMMENCEMENT OF PRODUCTION LOT UNITS.;; ;;NSWCPD IS THE ACCEPTANCE ACTIVITY FOR CDRL DATA ITEM A003. NSWCPD WAWF/IRAPT ACCEPTOR DODACC IS
"N64498".;; DATE OF FIRST SUBMISSION=ASREQ ;;SUPPLIER FORMAT IS ACCEPTABLE.;; ;;THE REPORT SHALL CONSIST OF OQED RECORDS LISTED IN CONTRACT UNDER AN/BRR-6 6W45/6W46 MOLD ASSEMBLY (DWG
8603517) MATERIAL/INSPECTION REQUIREMENTS: CERTIFICATE OF COMPLIANCE MATERIALS (ITEM NUMBERS 2,3,5,6 & 12) AND VISUAL/ DIMENSIONAL INSPECTION REPORT (ITEM NUMBERS 2,3,5,6 & 12).;;
;;APPROVAL OF THE REPORT BY NSWC PHILADELPHIA DIVISION IS REQUIRED PRIOR TO COMMENCEMENT OF FIRST ARTICLE.;; ;;NSWCPD IS THE ACCEPTANCE ACTIVITY FOR CDRL DATA ITEM A004. NSWCPD WAWF/IRAPT
ACCEPTOR DODACC IS "N64498".;; DATE OF FIRST SUBMISSION=ASREQ ;;SUPPLIER FORMAT IS ACCEPTABLE; ; ;;PLT REPORT SHALL CONSIST OF OQED RECORDS LISTED IN CONTRACT SECTION E: BULK CABLE
EXAM/INSPECTION/TEST REPORT (MIL-DTL-915/48); CERTIFICATE OF CONFORMANCE MATERIALS; CERTIFICATE OF COMPLIANCE MATERIALS; BULK CABLE EXAM/INSPECTION/ TEST REPORT (DWG 8590851, ITEM #5);
CABLE ASSEMBLY EXAM/INSPECTION/TEST REPORT AND MERCURY EXCLUSION CERTIFICATION.;; ;;APPROVAL OF THE REPORT BY NSWC PHILADELPHIA DIVISION IS REQUIRED PRIOR TO SHIPMENT OF PRODUCTION LOT
UNITS.;; ;;NSWCPD IS THE ACCEPTANCE ACTIVITY FOR CDRL DATA ITEM A005. NSWCPD WAWF/IRAPT ACCEPTOR DODACC IS "N64498".;;