Reference Number
|
12869048
|
|
Procuring Entity
|
DON EMILIO DEL VALLE MEMORIAL HOSPITAL
|
|
Title
|
ONE(1) LOT SUPPLY, DELIVERY, INSTALLATION, TESTING AND COMMISSIONING OF 12 UNITS HEMODIALYSIS MACHINES: TURNKEY PROJECT
|
|
Area of Delivery
|
Bohol
|
Printable Version
|
|
Solicitation Number:
|
2026-devmh-031
|
|
Trade Agreement:
|
Implementing Rules and Regulations
|
|
Procurement Mode:
|
Public Bidding
|
|
Classification:
|
Goods
|
|
Category:
|
Hospital / Medical Equipment
|
|
Approved Budget for the Contract:
|
PHP 35,000,000.00
|
|
Delivery Period:
|
120 Day/s
|
|
Client Agency:
|
|
|
|
Contact Person:
|
Agripina F Ceremones
BAC Secretariat
Bood,
Ubay
Bohol
Philippines 6315
63-38-5188309
63-38-5188309
Procurement@devmh.doh.gov.ph
|
|
Status
|
Active
|
|
Associated Components
|
Order
|
|
Bid Supplements
|
0
|
|
Document Request List
|
0
|
|
Date Published
|
31/03/2026
|
|
Last Updated / Time
|
31/03/2026 12:00 AM
|
|
Closing Date / Time
|
20/04/2026 10:00 AM
|
|
Description
|
Unit Description Quantity Unit Cost Total Cost
Lot "ONE (1) LOT SUPPLY, DELIVERY, INSTALLATION, TESTING, AND COMMISSIONING OF 12 UNITS HEMODIALYSIS MACHINES:TURNKEY PROJECT 1 35,000,000.00
35,000,000.00
Ten (10) units for operational use and Two (2) units as back up
All machines shall be brand new, unused, and of latest model
The offered machines must be CE-marked and/or FDA-cleared or its equivalent
Machine Specifications:
Monitor Display Size: At least 10 inches TFT-LCD touch screen
Water supply, Concentrate supply and Central supply
- or as per manufacturer"s specification
Electrical data:
-Power supply 100 to 240 V AC, 50 to 60 Hz
-Current consumption Approx. 9 A (at 230 V) and 15 A (at 110 V)
External connections
Network interface for data exchange with Therapy Data Management System (optional); input/output for connection of external auxiliary equipment; alarm
input/output (e.g. for nurse call); diagnosis for in-house computer diagnosis or its equivalent.
Battery: Built-in Battery that can continuously operate extra corporeal blood system during power interruption for at least 20 minutes.
Extracorporeal circuit
Arterial pressure monitoring:
-Display range - 300 mmHg to + 280 mmHg
-Accuracy ±10 mmHg
-Resolution 20 mmHg
-or per manufacturer"s specification
Venous pressure monitoring
-Display range - 60 mmHg to + 520 mmHg
-Accuracy ±10 mmHg
-Resolution 20 mmHg
or per manufacturer"s specification
Transmembrane pressure monitoring
-Display range - 60 mmHg to + 520 mmHg
-Resolution 20 mmHg
-or per manufacturer"s specification
Arterial blood pump
-Blood flow range 15 to 600 mL/min
-Accuracy ± 10%
-Resolution 5 mL/min
-Single needle system (op: With 2 blood pumps, internal pressure/pressure control with variable stroke volume (max. 50 mL/min)
-ISO-UF treatment program: Isolated Ultrafiltration (removing excess fluid from the body without removing solutes like urea or creatinine)
-Air bubble detector: Ultrasonic transmission measurement on blood line, additional optical monitoring in venous clamp or per manufacturer"s
specification
-Heparin pump: Heparin pump Delivery range: 0 to 10 mL/h
-Bolus function: max. 5 mL per bolus
-Syringe size: 20 mL
per manufacturer"s specification
Dialysis fluid circuit
Dialysis fluid flow range
-Selectable 0 – 300 – 500 – 800 mL/min Dialysate flow must have an automatic adaptive adjustment to effective blood flow to optimize treatment
efficiency
Dialysis fluid temperature
-Selectable 35°C to 39°C
or per manufacturer"s specification
Dialysis fluid conductivity
-Range 12.8 to 15.7 mS/cm (25°C)
-Accuracy ± 0.1 mS/cm
-Resolution 0.1 mS/cm
Dialysis fluid acid component
-Mixing ratio Adjustable, e.g. 1+44, 1+34
-Adjustment range 125 to 150 mmol/L
or per manufacturer"s requirement
Dialysis fluid bicarbonate component
-Default mixing ratio: 1 + 27.6 (others possible)
-Adjustment range - 8 to + 8 mmol/L
Online Clearance Monitoring
-Accurate Clearance K ± 6%
or its equivalent
Bicarbonate dry concentrate (Dry Bicarbonate Concentrate) or per manufacturer"s requirement
Dialysis fluid filter system: Machine must include dual-stage ultrafiltration system certified for ultrapure dialysate (endotoxin retention ≤ 0.10 EU/ml)
or its equivalent
Balancing accuracy ± 0.1 % according to the total dialysate volume
-Pressure holding tests Cyclic
or per manufacturers specification
Ultrafiltration:
-UF rate 0 to 4000 mL/h (in steps of 1 mL/h)
-Pump volume accuracy must be ±1% for UF, and ±10% for blood pump across full operating range
-Parameters displayed: UF goal, UF time, UF rate, UF volume
or per manufacturers specification
Blood leak detector
-Sensitivity ≤ 0.5 mL blood/min (Hct = 25) at max. flow 800 mL/min
as per manufacturer"s specification
BPM (optional): Display range
-Systole: 30 mmHg to 280 mmHg
-Diastole: 10 mmHg to 240 mmHg
-MAP: 20 mmHg to 255 mmHg
-Pulse: 20 to 245 1/min
-Accuracy ± 3 mmHg
-Resolution 1 mmHg
or per manufacturer"s specification
Disinfection and cleaning programs** ""Various programs combinations selectable. Technical changes reserved""
Rinse:
-Temperature/flow 37 °C / 600 mL/min
Hot rinse (recirculation)
-Temperature/flow 84 °C / 450 mL/min per manufacturer"s specification
Integrated hot rinse
-Temperature/flow 84°C / 450 mL/min
Cleaning
-Temperature/flow 37 °C / 600 mL/min
Heat disinfection
-Temperature/flow 84° C / 450 mL/min
Disinfection
-Temperature/flow 37 °C / 600 mL/min
or per manufacturer"s specification
Ancillary Systems & Infrastructure
Water Treatment System- Full setup of Reverse Osmosis (R.O.) system – Double Pass configuration
-Water capacity: 1,250L/H (7,920 GPD) gallons per day
-Rated voltage: AC220V, 50Hz, single-Phase 4-wire.
-Desalination rate: 99.8%.
-Recovery rate: 65%-85%. Ion removal rate: 99.5%-99.9%
-Bacteria & endotoxin remove rate: 99.8% Working temperature: 5-40°C.
-Tech adopted: pretreatment + RO system
-Pre-treatment: Sand filter, Active carbon filter, Water softener. Control: PLC control system adopted.
-Pure water quality:
-PH 5.0-7.0
-Nitrate ≤0.06μg/ml
-Cond. ≤5μS/cm
-Nitrite ≤0.02μg/ml
-Endotoxin ≤0.10 EU/ml
-Nh2 ≤0.3μg/ml
-TOC ≤0.50mg/L
-Microorganism 100CFU/ml
-Heavy metal ≤0.5μg/ml
or per manufacturer"s specification as to the complete operational set up and as approved by DOH licensing.
Working Process: Booster pump → sands filter → active carbon filter → water softener → PP filter → high-pressure pump→ RO system → RO tank
→ water using points
with Booster Pump, Sand Filter, Active Carbon Filter, Water Softener, PP Filter and High Pressure Pump
RO System: must have high desalination rate to treat water and get clean water for dialysis treatment. It removes the following water contaminants that may
be present in water: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium
Electrical Control System: All pipeline & fittings adopted in the whole plant are anti-corrosion material.
-Wire and cable will make use of famous brand which have good quality and long service life
as to the complete operational set-up
Components/Specification/Quantity
-Automatic sand filtration machine: 350kg 1 unit
-Automatic carbon filter machine: 50kg 1 unit
-Automatic softener: 140kg 1 unit
-Salt barrel: 200L 1pcs
-Raw water pump: 1 Unit
-Absolute Filters: 5*20"" 1 Unit
-PP filter: 5 um 5pcs
or as per appropriate complete set up
per manufacturer"s specification and DOH licensing
RO MODULE:/ or as per manufacturers set up and DOH Licensing Approval
-Control system: 1 SET
-RO Membrane: 8040 3 PCS
-High pressure pump: 2 PCS
Reprocessing Machines – Supply and installation of:
●One (1) four-station reprocessing machine
●Two (2) two-station reprocessing machines
Mixers – One (1) Bicarbonate Mixer, One (1) Acid Mixer
●Rotating mixing fully dissolves powder A and B.
●Regulated mixing procedure and prevent the loss of bicarbonate caused by excessive mixing of B solution
●All valves are made of anti-corrosion materials, which can withstand long term immersion of strong corrosive liquid and have long service life
●Filter: filter the undissolved particles in the dialysate to make the dialysate meet the requirements of hemodialysis and effectively ensure the quality
of the concentrate
●One-key/fully automatic disinfection program. After disinfection, the concentration of its participation meets the standard requirements
●PLC automatic control, 10-inch LCD touch screen online display, greatly convenient for the user"s operation
●Fully automatic liquid preparation program, with working modes of water injection, timing, mixing. filling etc.
●Fully automatic washing and one key disinfection procedures to effectively prevent bacterial growth
●The dispensing capacity can be arbitrarily selected to meet the needs of the hospital dialysis center
●Compact and integrated design to meet the combined installation requirements of various site conditions
●Control cabinet 1 Unit
●Mixing pump 1 Pcs
●Filter 1 Set
●Mixing tank 1 Unit
●Warranty card 1 PC
●User manual 1 Copy
or as per manufacturer"s set up requirements and DOH Licensing requirements
1.Hemodialysis Chairs – Twelve (12) ergonomically designed chairs suitable for dialysis patients
●3 Functions: back rest & leg rest lifting & height adjustable.
●Back and leg can be adjustable, easy to choose chair position and bed position or capable of Trendelenburg position
●Full leather cover, with foldable side table
Medical and Dialysis Appliances – Complete set up in compliance with DOH standards
1. Five (5) Units Vital Signs Monitor (BP, SpO2, PR, Contactless Thermometer) Standard Configuration:
-SpO2, NIBP, PR. Ear Temp, 3 Lead ECG
-Display: at least 8” inch color TFT capacitive touch screen
-Thermal Recorder
-Safety Standards
-ISO 13485:2016 approved, CE marking according to
-MDD93/42/EEC
-Operation Environment
-working Temp: 5-40°C
-Humidity: ≤93%
-Power Supply: 100-240V~, 50/60Hz±1Hz
-Battery Type: Rechargeable Lithium-ion battery
-Battery Capacity: (Working time: at least 3hours)
2. One (1) Unit Defibrillator
-Standard Configuration: Manual defibrillation, AED, 3/5-lead ECG, RESP, Thermal Recorder
-Optional: Pacer, NIBP, PR, EtCO2, SpO2
Safety Standards:
-Waveforms: Max 4 waveforms
-Ingress Protection: IP44 or per manufacturers specification
-Power requirement: 100-240V~, 50/60Hz±3Hz
-Battery type: Rechargeable Lithium-ion battery
-Battery capacity: 7500mAh, d.c.14.8V
-5000mAh, d.c.14.8V
-Battery number: 1 with built in battery, per DOH requirement
3. Pharmaceutical Refrigerator
-Volume: at least 200 liters
-Temperature Range: 2-8 deg C
-Forced air cooling & auto defrost
-LED digital display
-Microprocessor controller
-Sensor inside glycerin box
-Coated steel interior with 4 shelves
-Castors with leveling feet
-Built-in door locks
-at least 4 types of alarms, Audible and visual alarms
4. Wheelchair – 10 units
-Chrome plated steel frame, foldable stretcher
-Seat and back upholstery are made of waterproof leather
-Armrest cover with mattress
-Detachable leg rest 45-90°
-Original aluminum footplate
-8""front wheel and 24""rear wheel
-Backrest 50cm height, 46cm width
-Bilateral hand brake
-Weight capacity: at least 130kg
5. Emergency Cart – 2 units
-at least L750*W475*H920mm
-Defibrillator shelf with soft edge
-Extended surface with sliding 340*250mm
-Keyless lock Waste bin with lid
-Adjustable I.V. pole with 4 hooks
-Five Telescopic slides rail drawers with easily dividers inside with card to record
-ABS soft edge Cardiac Boards
-Oxygen tank holder
6. ECG Machine – 1 unit
Technical Specs: 12 LED ECG Machine with complete accessories, must be DOH Approved, rechargeable
-Display: 6.2 inches LED color touch screen
-Resolution: 800×480
-Display Data: Patient ID, gender, age, waveforms, recording/sweep speed, gain, EMG filter,
-HR, leads status, clock, information message, network and USB, battery status
-Display format: 3×4, 6×2, simultaneously 12 leads display
-Brightness: Automatic adjustable according to operating environment
-Manual from 1 to 10
Processing
-ECG Analysis Sampling Rate: 1000samples/sec (sps)
-Digital Sampling Rate: 1000samples/sec/channel
-Acquisition Mode: pre/post-acquisition
-10 seconds instantaneous ECG acquisition
-Dynamic Range: AC differential±10mV, DC offset± 650mV
-Resolution: 0.2μV/LSB@1000sps
-Frequency Response: -3dB@0.05Hz-150Hz
-Baseline Drift Filter: 0.05Hz, 0.1Hz, 0.2Hz, 0.5Hz
-High Cut-off Frequency: 25Hz, 35Hz, 45Hz, 75Hz, 100Hz, 150Hz
-AC Filter: 50/60Hz ±0.1Hz
-CMRR: ≥110dB
-ADC: 24bit
-Input Impedance: ≥50MΩ
-Patient Leakage: <10μA
-HR Meter: 30-300 bpm ±1% or 1bpm
-Startup Time: around 10 seconds
-Gain/Sensitivity: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV,
-20/10mm/mV,10/5mm/mV and AGC
Power
-Power supply: AC input/Battery Operation
-AC Power
-Input Voltage: 100-240V~
-AC Frequency: 50Hz/60HZ±1Hz
-Input Power: 40VA
-Battery
-Battery Type: Rechargeable Lithium-ion Battery
-Battery Capacity: 11.1V typical, 2600mAh
-7 hours of continuous operation without recording/
-500 ECGs or conduct continuous recording for 2 hours
-Battery Charge Time: 3.4 hours with power off
Recorder
-Recording Tech: Thermal dot-matrix
-Recorder Width: 80mm
-Recording Paper: 80mm×70mm Z-fold
-80mm×20m Rolled
-Valid Recording Width: 72mm
-Paper Speed: Manual: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s
-Auto& Rhythm: 25mm/s, 50mm/s
-Recording format: 3×4, 3×4+1R, 1×12, 1×12+1R
-External printer format: 3×4, 3×4+1R, 3×4+3R, 6×2, 6×2+1R, 1×12, 1×12+T
-Recorder Resolution: Horizontal 40dots/mm, vertical 8 dots/mm @ 25mm/s Software
-Measurement & Interpretation: COMEN ECG analysis algorithm
-Internal Storage: Standard 8G micro-SD card for 40000 ECGs internal memory
-ECG Storage Format: Picture format.jpg and binary format .bin (PCECG or h2 print)
-Multi-Language: Chinese & English (Temporarily)
-Diagnostic Review: 10 minutes review for all 12 leads waveform info.
-Hardware support: Built in WIFI module/ keyboard, mouse and scanner optional
-Stand By function: Resume less than 10sec
-Patient record fuzzy search function: Patient name, ID, diagnostic time.
Environmental Specs
Temperature
-Operating: 5℃ to 40℃
-Transport & storage: -20℃ to 60℃
Humidity
-Operating: ≤90%
-Transport & storage: ≤93%
Pressure
-Operating: 700hPa to 1060hPa
-Transport & storage: 700hPa to 1060hPa
7. Mayo Table – 5 units
The leg is made of stainless-steel sheet (2mm thickness) with at least four (4) swivel castor. The table is made of stainless-steel sheet (1mm thickness)
with list on each side. Assembled with TIG welding process.
Height: the pole made of stainless pipe (31.8mm & 12.7mm) and adjustable with pin lock.
Castor: Four 2” swivel castor
Max Load: 15kg
Dimension: Approx L(570)x W(430) x H (860)-1085mm
Packaging: Knock Down System for 35103 K model
8.Portable Suction Machine – 3 units
Technical Specifications:
- Powerful-adjustable Vacuum power at -75 kPa / -563mmHg
- Noise level at 51.2 dB(A) (Max. Operation)
- With overflow/virus filter
- Vacuum regulator: Membrane type with safety knob (with locking mechanism)
- Vacuum regulator with safety knob
- IEC 60601 safety rating - Type CF (Cardiac Floating: Max earth leaking current 10μA) for protection against electric shock and direct conductive contact
with heart
- Ingress protection: IP21
- Manufacturer Certification: CE / ISO approval
- Carrying handle for easy mobility
-With tubing holder
- 2 integrated front and side jar holder
Inclusions:
- 1 unit AC/DC
-1 Overflow protection / virus filter set
- 1 Silicone tubing
- 1 Suction Jar, Polycarbonate, 1.5L
- 1 unit Adapter
9. Nebulizer – 3 units
Metal Frame Motor Construction
Unique Four-Pole Motor Design Extends Life of the Unit
Large Built-In Compartment for Storing Nebulizers and Tubing
Built-In Nebulizer Holder
Easy to Use
Noise: 51 to 55 dBA
Maximum Liter Flow: 12 LPM
Maximum Air Pressure: 30 PSIG
Compressor Free Air Flow: 9 LPM or Greater
Must have spare filter 5 pieces per unit
Support Infrastructure and Office Set Up – Initial office supplies, furniture, and equipment
1. Desktop Computer Set – 2 unit Specifications:
•Branded – Traditional Tower Desktop
•Processor: Intel Core i5 or Up
•Base Frequency: 2.9 GHz.
•Turbo Frequency: 4.8 GHz.
•Cache: 16MB Cache
•No. of Cores: 8 Cores
•Lithography: 14mm
•Threads: 16 Threads
•Thermal Design: 69W
•Memory: 8GB RAM or Higher
•Storage/Hard Disk: 500GB or Higher Hard Drive, 7200rpm, 3.5” + 256GB Solid State Drive
•Graphics/Video Processor: 4GB
•Network Interface: Gigabit Ethernet 10/100/1000
•Wireless LAN: WI-FI 802.11 ax; Bluetooth Version 5.0
•Standard I.O Ports: Front: Two (2) USB 3.0 ports; Two (2) USB 2.0 ports; Rear: Two (2) USB 3.0 ports; Two (2) USB 2.0 ports;
•One (1) USB Type C Port
•One (1)headphone/speaker/Combo jack
•One (1) Ethernet RJ-45 Port
•One (1) HDMI port
•One (1) Display Port
•Pointing Devise: USB Optical mouse with No. mouse pad
•Input Device; USB Keyboard with numeric keypad
•Security: USB enabled/disable (via BIOS) Power-On Password (via BIOS) Setup Password (via BIOS)
•Operating System: Windows 10 Professional 64-Bit or higher
•Software: MS Office 2013 or higher Standard edition Full
Display Screen:
1. Branded
2. 21.5” LED Monitor (VGA) + HDMI)
3. Resolution: 1920 x 1080
2. 3-in-1 Wireless Printer – 2 units COMPUTER PRINTER, (PRINT, SCAN, COPY) ALL-in-ONE TANK
SPECIFICATIONS:
1. Handle a variety if print jobs with 150 sheets paper tray adjustable for different paper sizes and an additional single-sheet manual feed slot for
various paper types.
2. Auto document feeder (ADF) allows for convenient scanning and copying multiple pages.
3. Refill Ink Tank printers features a transparent cover
4. With control panel 1.44"" Colour LCD Screen
5. Color and monochrome printing capable
6. Supports the OS Windows 7 SP1/8.1/10 Server 2008/2008 r2/2012/2012 R2/2016/2019
•products must comply with the latest version of the International ENERGY STAR requirements (currently version 2.0 for Imaging Equipment).
•product must contain user instructions for green performance management.
product must be capable of using recycled content paper without voiding the manufacturer’s warranty.
3. White Board – 1 unit
•WHITE BOARD 12X24 INCHES
•WHITE BOARD 24 x 48 INCHES
•WHITE BOARD 35 X 50 INCHES
•WHITE BOARD 48x36ft
4. Cork Board – 1 unit
•CORK BOARD W/ ALUMINUM FRAME , APPROX. 24""X36"" (600X900mm)
•CORK BOARD W/ METAL FRAME - 36x24""
•CORK BOARD W/ METAL FRAME , 2X3 FEET HANGING
•CORK BOARD W/ METAL FRAME 36 X 30 INCHES
•CORK BOARD, 60 X 90 CM
•CORK BOARD W/ METAL FRAME 36 X 30 INCHES
•CORK BOARD, 60 X 90 CM
5. Office Chair – 6 units Ergonomic Chair, leather type, Regular
• products made of plastic materials which do not contain lead, chromium, cadmium, mercury, phthalates, and halogenated organic substances.
•The chairs shall be marked for recycling according to ISO 11469 or equivalent and must not contain additions of other materials that may hinder their
recycling.
• packaged in recyclable material.
6. Chair for Relatives (Monoblock)–12 units
•products must not contain lead, chromium, cadmium, mercury, phthalates, and halogenated organic substances.
•The chairs shall be marked for recycling according to ISO 11469 or equivalent and must not contain additions of other materials that may hinder their
recycling.
•products must be packaged in recyclable material
7. Gang Chair (Waiting Area) – 2 units
GANG CHAIR WITHOUT ARMREST (4 SEATERS STAINLESS STEEL)
SPECIFICATIONS:
1. Can accommodate at least 4 seaters
2. Steel: Arm and leg frames with chrome plated finish
3. at least 150kg weight rating per seat
4. Perforated seat and back
5. Silver/Black
•The chairs shall be marked for recycling according to ISO 11469 or equivalent and must not contain additions of other materials that may hinder their
recycling.
• products must be packaged in recyclable material.
8. Water Dispenser - 2 unit
WATER DISPENSER, HOT AND COLD, BOTTOM LOADING
9.Microwave - 2 unit
Technical Specs.
Digital/ inverter
at least 30 liters
10. 1 adult Digital Weighing Scale stand type
Tech Specs:
Capacity: 150-300 kilograms
High Precision
With HEIGHT Rod
Rechargeable and easy adaptor
with LCD screen
Medical Grade
with BMI function
11. 1 Digital patient stretcher weighing scale.
Capacity: 450 kilograms
with LCD display
Functions: Net/Gross, Hold/release, Metric Conversion, Height, Entry of BMI
With Power Adaptor
Medical Grade
12. BIOMEDICAL REFRIGERATOR – 1 unit
2-DOOR GLASS, 5 LAYER SHELVES, 628L CAPACITY
Technical Specifications:
*Temp. Range: 2~8°C
*Temp. Accuracy: 0.1°C
*Control System: Microprocessor control, Digital tube display
*Alarm: High and low temperature alarm, Power fault alarm, Thermostat fault alarm, Door ajar alarm
*Refrigeration Type: Air-cooled
*Refrigerant: R134a, CFC-free, 175g
*Condenser & Evaporator: Copper tube and aluminum fin, Bundy tube
*Defrost: Auto defrost
*With 1 unit of AC Automatic Voltage Regulator
• fulfils at least ENERGY STAR 5.0.
•does not contain “controlled refrigerants” as defined under the Ozone Layer Protection Regulation.
• products are repairable and that replacement parts are available (for minimum of 10 years after end of production).
• products must be in recyclable packages.
13. REFRIGERATOR, 7.4 cu. Ft –
• fulfils at least ENERGY STAR 5.0.
• do not contain “controlled refrigerants” as defined under the Ozone Layer Protection Regulation.
• products are repairable and that replacement parts are available (for minimum of 10 years after end of production).
• products in recyclable packages
14. Pulse Oximeter – 2 units
Technical Specification
a) Display: At least 240x64pixels resolution, mono graphic LCD
b) Contrast control: 1-9
c) Backlight control: On, Off
d) Measurement range: 0-100%
e) Pulse rate: 15-30 bpm
f) Perfusion Index: 0.05% to 20%
g) Saturation accuracy: Adult ±3% 70 to 100%, Neonate 50-69% ±4%
h) Average time: 2,3,8,12 secs
i) Alarm volume: 0 (off)- 7, Alarm silence 2 min
j) Trend time: 1-48hours, tabular and graphical
k) Weight must not higher than 1kg
l) Dimension must not higher than 24.5cm x 8.4cm x 8.5cm
m) Standards: IEC60601-1, PX1, EN475, EN/IEC 60601-1-2, ISO9919
n) With RS232 digital output from serial port
o) Power requirement: 100-240Vac, 50/60Hz, with LI-ION battery 3hours capacity.
p) for adult, pedia and neonate
q) with 2 selectable working mode, spot and continuous
r) display parameters: pulse rate, SpO2 percentage, SpO2 limits, pulse rate limits, wave form alarm status, trend, battery status, current time and
perfusion index with 1 extra probe for adult, pedia and neonate, with complete accessories
15. STETHOSCOPE, ADULT, HEAVY DUTY 4 units
(BRANDED) brand is commonly used by doctors
• Detects Korotkoff sounds of blood pressure and subtle heart murmurs
• Stainless steel chest piece intensifies body sounds transmitted through tissues
• Comfort Sealing ear tips for soft, yet airtight fit
• Not made with natural rubber latex
• Excellent for general auscultation and blood pressure
• Stainless steel double-head (bell and flat diaphragm) chest piece
• Non-chill rim
• Not made with natural rubber latex
• Rotatable binaural and interchangeable comfort sealing ear tips
16. STETHOSCOPE, PEDIA, HEAVY DUTY 4 Units
(BRANDED)- brand is commonly used by doctors
• Detects Korotkoff sounds of blood pressure and subtle heart murmurs
• Stainless steel chest piece intensifies body sounds transmitted through tissues
• Comfort Sealing ear tips for soft, yet airtight fit
• Not made with natural rubber latex
• Excellent for general auscultation and blood pressure
• Stainless steel double-head (bell and flat diaphragm) chest piece
• Non-chill rim
• Not made with natural rubber latex
• Rotatable binaural and interchangeable comfort sealing ear tips
17. Glucometer – 1 unit with two box of strips
Accuracy Standard: The device should be compliant with the latest ISO 15197:2013 standards for blood glucose monitoring systems, ensuring a high level of
accuracy when compared to laboratory results.
18. STRETCHER TROLLEY – 2 unit
Transfer Stretcher with Transfer Mattress, IV Pole, Oxygen Tank Holder, Receptacle & Hanger Top
TECHNICAL SPECIFICATIONS:
Total Height: 510 – 850 mm
Back Raise Angle: 0º – 70º
Casters: 150mm diameter with central locking system
Safe Working Load: 153 kg (1500N)
Transfer Mattress Thickness: at least 4 inches
Surface Material: Polyester
Padding: Urethane Foam
Frame Material: Steel with electro-deposition and Partially Aluminum
Mattress base material: Polypropylene (PP) or its equivalent
Transfer board material: Polypropylene (PP) or its equivalent
Storage tray capacity: 10 kg
Inclusion:
a) IV Pole
b) Foam Mattress
c) Oxygen Tank Holder
• Pass the safety standard for:
- EN1865
- Classification according to Directive 93/42/EEC: Class
• Central locking system with seesaw pedal type
• It has a color-coded lock pedal on the casters, red if lock and green if unlock.
• Has a 100mm diameter center wheel.
• Has IV Pole holder is equipped in four corners.
• It has a storage for the IV pole when not in use
• Accessory rail is located on both sides of bed
• Lever is gas cylinder assisted.
• Has oxygen cylinder Holder with diameter of 100-115mm and can be mounted either vertically or horizontally at the head side and has a load capacity of
15kg.
• The mattress has two handles on each side
19. Thick Blankets - 20 Units plain color
20. Smart TV 43"" inch 2 Units with swivel type bracket
21. Dialysis Consumables
good for 200 complete dialysis treatments
Terms & Conditions:
Compliance & Documentation:
●Authorized/Exclusive Distributorship from principal of hemodialysis machine.
●Product brochure or technical data sheet in English
●Valid and current ISO 13485 certificate of the manufacturer
●Warranty Certificate: 12 months machine and parts;
●Technical Service support availability 5 years.,
●Free Annual Calibration and Preventive Maintenance, including maintenance kit for 5 years
●Calibration certificate to be provided upon installation.
●Supplier must have satisfactorily supplied and installed hemodialysis machine from at least 5 Government/DOH Hospital
●Supplier must have employed qualified Engineers/Technician on Hemodialysis Set up and RO System
●Supplier shall handle the necessary piping works and electrical system, reverse osmosis, water system, and hemodialysis treatment processes at no cost
to Don Emilio Del Valle Memorial Hospital
●Supplier shall shoulder the DOH required water testing in accordance with the DOH assessment tool and License to Operate without any cost to Don Emilio
del Valle Memorial Hospital
●Provide comprehensive training to dialysis personnel:
a. Nurse- basic operation of the machines and related clinical processes
b. Technician Operation and Basic troubleshooting of dialysis machine, RO System, Mixers and others
c. Office assistants and billing clerks-administrative needs when running a hemodialysis facility.
d. Pollution Control Officers- on waste management disposal
●The offered machine must comply with IEC 60601-1 (electrical safety) and IEC 60601-1-2 (EMC).or its equivalent
●The brand of dialysis machine must have been registered in the Philippine market for at least 15 years
Training & Support:
●Training for Nurses, Hemodialysis Technicians and Pollution Control Officer.
●Marketing support (tarpaulin, social media, etc.).
●Manual of Procedures (Clinical Department and Hemodialysis Machines).
●Monitoring support for PhilHealth
●Delivery Term: 120 Calendar Days"
|
|
|
|
Pre-bid Conference
|
|
Date
|
Time
|
Venue
|
|
07/04/2026
|
10:00 AM
|
MCC CONFERENCE ROOM, ADMINISTRATIVE BLDG., DEVMH COMPOUND, BOOD, UBAY, BOHOL
|
|
|
|
|
|
|
|
Created by
|
Agripina F Ceremones
|
|
Date Created
|
19/03/2026
|
|
|
|
|