Centralized Fire Alarm Monitoring System CFAMS (Бахрейн - Тендер #60547408) | ||
| ||
| Для перевода текста тендера на нужный язык воспользуйтесь приложением: | ||
Страна: Бахрейн (другие тендеры и закупки Бахрейн) Организатор тендера: Tender Board - Kingdom of Bahrain Номер конкурса: 60547408 Дата публикации: 08-01-2025 Источник тендера: Tender Board - Kingdom of Bahrain |
||
Tender Number: 1/2025/MOW (IN/MOW/2024/700)
PA Ref Number: IN/MOW/2024/700
Tender DescriptionWith the introduction of said CFAMS system any fire alarms in unmanned substations within the Tubli WPCC will be monitored and communicated by the STP control room and security gate personnel to the Fire department and concern staff immediately The Fire alarm monitoring system at Tubli Water Treatment Plant for detecting and notifying fire alarms at Substations would be integrated via LPUs using existing SCADA FOC Fiber Optic Communication ring The alarm notifications and beef sounds will be displayed on two Repeater panels located in STP control room and Security Room accordingly The Fire Alarm Panel signal will be connected to a Modbus Gateway module Moxa ioLogik for interfacing with the existing communication channels and the FAMS at HYBACS substations will be incorporated into the SCADA using FlexEdge module
Issued by Ministry of Works Category/Sector General Internal/External Internal Initial Bond BD 500 Bid Validity / Initial Bond Validity Period (Days) 180 days Tender Fees BD 15 Contract Duration 2 Month Is Alternate Bid Allowed Yes Publish Date Wednesday, 08 January 2025 Purchase Before Tuesday, 14 January 2025 Closing Date Sunday, 19 January 2025 Opening Date Monday, 20 January 2025 Additional NotesWith the introduction of said CFAMS system any fire alarms in unmanned substations within the Tubli WPCC will be monitored and communicated by the STP control room and security gate personnel to the Fire department and concern staff immediately
The Fire alarm monitoring system at Tubli Water Treatment Plant for detecting and notifying fire alarms at Substations would be integrated via LPUs using existing SCADA FOC Fiber Optic
Communication ring
The alarm notifications and beef sounds will be displayed on two Repeater panels located in STP control room and Security Room accordingly
The Fire Alarm Panel signal will be connected to a Modbus Gateway module Moxa ioLogik for interfacing with the existing communication channels and the FAMS at HYBACS substations will be
incorporated into the SCADA using FlexEdge module
1. يهدف مشروع نظام إنذار الحريق المركزي لتوصيل و ربط و مراقبة أجهزة الإنذار و مكافحة الحريق الموجودة في محطات الكهرباء الفرعية و المرفقات الأخرى في مركز توبلي لمعالجة مياه الصرف الصحي بكل من غرفة التشغيل و التحكم الرئيسية في المركز غرفة الأمن الدفاع المدني و الجهات الأخرى ذات العلاقة بشكل مباشر سيتم عمل التوصيل الخاص بنظام الحريق المركزي المطلوب من خلال شبكة خطوط الألياف الضوئية و ألواح الإتصال الموجودة في مركز توبلي و الخاصة بنظام التحكم و التشغيل SCADA بحيث سيتم نسخ و عكس لوحات التحكم في نظام الحريق في الأماكن المذكورة المراد ربطها بأجهزة الحريق في المواقع
For further inquiries please contact on:
Ministry of Works
17545958